Analysis of the Performance and Electricity Consumption of Centrifugal Pumps using Trimming Impellers

Analysis of the Performance and Electricity Consumption of Centrifugal Pumps using Trimming Impellers

  IJETT-book-cover           
  
© 2023 by IJETT Journal
Volume-71 Issue-5
Year of Publication : 2023
Author : Ahmad Yani, Ratnawati, Dwi Irawan, Kemas Ridhuan, Dwi Raharjo, Dedy Daud, Rudi Hernawan
DOI : 10.14445/22315381/IJETT-V71I5P230

How to Cite?

Ahmad Yani, Ratnawati, Dwi Irawan, Kemas Ridhuan, Dwi Raharjo, Dedy Daud, Rudi Hernawan, "Analysis of the Performance and Electricity Consumption of Centrifugal Pumps using Trimming Impellers," International Journal of Engineering Trends and Technology, vol. 71, no. 5, pp. 282-289, 2023. Crossref, https://doi.org/10.14445/22315381/IJETT-V71I5P230

Abstract
Centrifugal pumps are essential in various industries in various parts of the world. Pump performance and electricity consumption are highly considered in the selection and use of centrifugal pumps, especially to meet industrial needs that do not comply with pump specifications. Impeller trimming is a method of reducing the size of the impeller diameter from its original size to maximize pump performance and efficiency. In this study, the pump performance was analyzed using an original impeller with a diameter of 130 mm and a trimming impeller with a diameter of 108 mm. The results of this study indicate that the use of impeller trimming with a diameter of 108 mm works according to the target operation, namely to produce a capacity of 2.5 m3/H at a head of 10 m so that it can increase pump efficiency by 29% and reduce electricity consumption by 33.387%.

Keywords
Centrifugal pump, Impeller trimming, Pump performance and electricity consumption.

References
[1] Saurabh Goswami, “Multiphase Pumping to Enhance Oil Recovery,” International Journal of Engineering Trends and Technology, vol. 21, no. 2, pp. 67–71, 2015.
[CrossRef] [Publisher Link]
[2] Hongliang Wang et al., “Effects of the Impeller Blade with a Slot Structure on the Centrifugal Pump Performance,” Energies, vol. 13, no. 7, 2020.
[CrossRef] [Google Scholar] [Publisher Link]
[3] S. Chakraborty, KM Pandey, and B. Roy, "Numerical Analysis on Effects of Blade Number Variations on Performance of Centrifugal Pumps with Various Rotational Speeds," International Journal of Current Engineering and Technology, vol. 2, no. 1, pp. 143-152, 2012.
[Google Scholar] [Publisher Link]
[4] A. Farid Ayad Hassan, H. M. Abdalla, and A. S. Abo El-Azm Aly, “Effect of Impeller Blade Slot on Centrifugal Pump Performance,” GlobalJournal of Researches in Engineering, vol. 16, no. 4, 2016.
[CrossRef] [Google Scholar] [Publisher Link]
[5] Mario Šavar, Hrvoje Kozmar, and Igor Sutlović, “Improving Centrifugal Pump Efficiency by Impeller Trimming,” Desalination, vol. 249, no. 2, pp. 654–659, 2009.
[CrossRef] [Google Scholar] [Publisher Link]
[6] Davood Khoeini, and Ebrahim Shirani, “Influences of Impeller Splitter Blades on the Performance of A Centrifugal Pump with Viscous Fluids,” International Journal of Fluid Machinery and Systems, vol. 11, no. 4, pp. 400–411, 2018.
[CrossRef] [Google Scholar] [Publisher Link]
[7] Gamal R.H. Abo Elyamin et al., "Effect of Impeller Blades Number on the Performance of A Centrifugal Pump," Alexandria Engineering Journal, vol. 58, no. 1, pp. 39–48, 2019.
[CrossRef] [Google Scholar] [Publisher Link]
[8] Dadapeer D, and Veeresh G Gunjalli, “Analytical Study of Performance of A Centrifugal Pump for Different Operating Conditions,” International Journal of Engineering Trends and Technology, vol. 54, no. 3, pp. 175–179, 2017.
[CrossRef] [Publisher Link]
[9] Paul Waide, and Conrad U Brunner, “Energy-Efficiency Policy Opportunities for Electric Motor-Driven Systems,” The International Energy Agency, p. 132, 2011.
[CrossRef] [Google Scholar] [Publisher Link]
[10] Arun Shankar Vishnu Kalaiselvan et al, “A Comprehensive Review on Energy Efficiency Enhancement Initiatives in Centrifugal Pumping Systems,” Applied Energy, vol. 181, pp. 495–513, 2016.
[CrossRef] [Google Scholar] [Publisher Link]
[11] G. Kalyan K.L.N. Murty, "Design and Optimization of Centrifugal Pump Guide Vanes," SSRG International Journal of Mechanical Engineering, vol. 2, no. 2, pp. 9-14, 2015.
[CrossRef] [Publisher Link]
[12] Fan Yang, Hao-ru Zhao, and Chao Liu, “Improvement of the Efficiency of the Axial-Flow Pump At Part Loads Due to Installing Outlet Guide Vanes Mechanism,” Mathematical Problems in Engineering, vol. 2016, pp. 1-10, 2016.
[CrossRef] [Google Scholar] [Publisher Link]
[13] Sustainability Victoria, “Energy Efficiency Best Practice Guide, Pumping Systems, 2009. [Online]. Available: http://www.sustainability.vic.gov.au/~/media/resources/documents/services and advice/business/srsb em/resources and tools/srsb em best practice guide pump 2009.pdf
[14] Wen Guang Li, “Impeller Trimming of An Industrial Centrifugal Viscous Oil Pump,” International Journal of Advanced Design and Manufacturing Technology, 2011.
[Google Scholar] [Publisher Link]
[15] ME Matlakala et al., “Influence of Impeller Diameter on the Performance of Centrifugal Pumps,” IOP Conference Series: Materials Science and Engineering, vol. 655, no. 1, 2019.
[CrossRef] [Google Scholar] [Publisher Link]
[16] Keran Shu et al., “The Effect of Impeller Cut on the Performance of Middle Specific Speed Centrifugal Pump,” IOP Conference Series: Materials Science and Engineering, vol. 394, no. 3, pp. 1-5, 2018.
[CrossRef] [Google Scholar] [Publisher Link]
[17] Khoeini Davood, and Tavakoli Mohammad Reza, “Flow Characteristics of a Centrifugal Pump with Different Impeller Trimming Methods,” FME Transaction, vol. 46, no. 4, pp. 463–468, 2018.
[CrossRef] [Google Scholar] [Publisher Link]
[18] M. Shadab et al., “Effect of Impeller Shroud Trimming on the Hydraulic Performance of Centrifugal Pumps with Low and Medium Specific Speeds,” Engineering Applications of Computational Fluid Mechanics, vol. 16, no. 1, pp. 514–535, 2022.
[CrossRef] [Google Scholar] [Publisher Link]
[19] Bubryur Kim et al., "Optimization of Centrifugal Pump Impeller for Pumping Viscous Fluids Using Direct Design Optimization Technique,"Machines, vol. 10, no. 9, 2022.
[CrossRef] [Google Scholar] [Publisher Link]
[20] Mohamed Hassan Gobran et al., “Numerical Simulation of Centrifugal Pump and Effect of Impeller Geometry on Its Performance,” Engineering and Applied Sciences, vol. 4, no. 2, p. 21, 2019.
[Google Scholar] [Publisher Link]
[21] Kapil Rangari, and Ravindra Gandhe, "Design and Failure Analysis of Pneumatic Operated 2" Diaphragm Pump," SSRG International Journal of Mechanical Engineering, vol. 5, no. 5, pp. 32-39, 2018.
[CrossRef] [Publisher Link]
[22] Yuxing Bai et al., "Effects of Impeller DiameteEffects of Impeller Diamete,” Mathematical Problems in Engineering, vol. 2017, p. 15, 2017.
[CrossRef] [Publisher Link]
[23] V.K. Arun Shankar, "Real time simulation of Variable Speed Parallel Pumping system," Energy Procedia, vol. 142, pp. 2102-08, 2012.
[CrossRef] [Google Scholar] [Publisher Link]
[24] E. Nørgaard et al., “Performance of Components of Ice Slurry Systems: Pumps, Plate Heat Exchangers, and Fittings,” International Journal of Refrigeration, vol. 28, no. 1, pp. 83–91, 2005.
[CrossRef] [Google Scholar] [Publisher Link]
[25] Pratik Kasat et al., “Developing a Digital Twin of Centrifugal Pump for Performance Evaluation,” Materials Today Proceedings, vol. 72, pp. 1798-1802, 2023.
[CrossRef] [Google Scholar] [Publisher Link]
[26] Wenke Zhang et al., “Analysis and Optimization of the Performance for the Ground Source Heat Pump System with the Middle-Deep U-Type Well,” Applied Thermal Engineering, vol. 219, 2023.
[CrossRef] [Google Scholar] [Publisher Link]
[27] Kai Wang et al., “Effects of Impeller Trim on Performance of Two-Stage Self-Priming Centrifugal Pump,” Advances in Mechanical Engineering, vol. 9, no. 2, 2017.
[CrossRef] [Google Scholar] [Publisher Link]
[28] Sutardi Sutardi, and Ridwan Adliansyah, “Effect of Impeller Trimming on Centrifugal Pump,” Rekayasa Mesin, vol. 12, no. 3, pp. 663–675, 2021.
[CrossRef] [Google Scholar] [Publisher Link]
[29] Arun Shankar V.K. et al., "Sensorless Parameter Estimation of VFD Based Cascade Centrifugal Pumping System Using Automatic Pump Curve Adaptation Method," Energy Reports, vol. 7, pp. 453–466, 2021.
[CrossRef] [Google Scholar] [Publisher Link]